Gypsum Free Articulator joy Art-1,2/Arti-SB

Gypsum Free Articulator joy Art-1,2/Arti-SB

Gypsum Free Articulator joy Art-1,2/Arti-SB Made in Korea

Description

Features
Joy Art / Arti-SB articulator is a new innovative articulator without using dental plaster. 
It is a new articulator system which is used with Joy Mold to avoid pin working.
- Save materials
- Save working time
- Protect a plaster model
- Good for environment conservation
- Easy working

part list

Joy Art-1
J10 LOWER BODY
J11 UPPER BODY
J12 CONNECTOR
J13 NECK OF BALL
J14 BALL HOLDER (RIGHT SCREW)
J15 BALL HOLDER (LEFT SCREW)
J16 CLAMPING SCREW
J17 MAGNETIC & HOUSING
101 RIVET
102 SPRING
103 SNAP RING
104 HEIGHT ADJUSTABLE BOLT & NUT

Joy Art-2
J20 LOWER BODY
J21 UPPER BODY
J22 CONNECTOR
J23 NECK OF BALL
J14 BALL HOLDER(RIGHT SCREW)
J15 BALL HOLDER(LEFT SCREW)
J16 CLAMPING SCREW
J27 MAGNETIC & HOUSING
101 RIVET
102 SPRING
103 SNAP RING
104 HEIGHT ADJUSTABLE BOLT & NUT

Arti-SB
A10 LOWER BODY
A11 UPPER BODY
A12 CONNECTOR
A13 NECK OF BALL
J14 BALL HOLDER(RIGHT SCREW)
J15 BALL HOLDER(LEFT SCREW)
J16 CLAMPING SCREW
J17 MAGNETIC & HOUSING
101 RIVET
102 SPRING
103 SNAP RING
104 HEIGHT ADJUSTABLE BOLT & NUT

ACCESSORIES
201 DRIVER
207 JOY HOLDER-1
208 JOY HOLDER-2
212 BOLT,
213 STEEL PLATE (Φ 18)
214 STEEL PLATE (Φ 21)

Joy Art system is using Joy Mold to make a easy working of separating model and mounting.

1. Making a plaster model by using Joy Mold.

① trim equally the end of impression model by knife or scissors as shown in Fig. 1
It is better to make enough plaster height which need separting model to produce dental prosthetic appliance.

 

② It is better to make a hole or make 4 ~ 5mm plaster steps and give an angle of inclination to the outside as shown Fig. 2 and Fig. 3 for easy picking up separation plaster model.

③ Pour plaster to impression model and Joy Mold. And then place Joy Mold to suitable position on the impression model.. It will be better to trim extra plaster by hand or knife before hardening of plaster.
It is better to mark the midline on the impression model and match same line of Joy Mold midline.
When you work with partial mold, it is better to put steel plate (Part No. 213) firstly and then pour plaster. 
④ When the tray size and Joy Mold is not matched well, it is better to place Joy Mold to the Prosthetics teeth.It is better to pour plaster to the Prosthetics teeth firstly. Put the Joy Mold to the articulator and then pour plaster to the opposite teeth after placing mold which make a good position to put articulator smoothly as shown Fig. 4.
⑤ Make equally as possible as lower Joy Mold and upper Joy Mold when you make impression tasking with bite tray as shown Fig. 3. It is possible to happen the mismatching between Joy Mold and articulator (Joy Art 1/Arti-SB) when the mold is not parallel.
It is better to pour plaster to the prosthetics teeth firstly. Put the Joy Mold to the articulator and then pour plaster to the opposite teeth after placing mold which make a good position to put articulator smoothly as shown Fig. 4.

 

⑥ Saw the plaster model after hardening plater totally. Saw the plaster model and Joy Mold to the 1st step of Joy Mold as shown Fir. 5. It will be possible not to separate plaster model from mold if you do not saw the plaster model and mold until the 1st step of mold. It will be possible to shake the plater model if you saw the mold too deeply.
Trim the sharp point or rough point of mold cutting part by knife. Blow dust by air-gun on the plaster model and in the mold. Attention not to remain plaster dust or plastic dust in the mold during working.

⑦ It is possible to saw both of the plaster model and Joy Mold when you work short crown. However, it is better to work by back sawing when you work small tooth such as the lower anterior tooth or more than two teeth

⑧ Use the hole which is in the bottom of mold when you want back sawing. It is possible to make a hole as position you want and hit the end of mold by steel rod as shown Fig. 7.
In case of short plaster model or 3~4 teeth plaster model, it is possible to separate the plaster model from the mold without using steel rod.

 

⑨ Use Jig (Joy Holder) when you saw plaster model and mold as shown Fig. 8. It is better to work above dust collector.

⑩ Use base plate with plaster model which is making without Joy Mold. Stick by super glue mold and plaster model after trim the model as shonw Fig. 9. In case of the working model, make the plaster base in the Joy mold and trim the model enough size. Match with Joy Mold by plaster and sawing the model as shown Fig. 10

2. Mounting working

① Conneting and fix the upper and lower plaser cast on the right position with using dental wax as shown Fig. 11

② Put the lower model to the Joy Art / Arti-SB articulator.
③ Loose the bolt of articulator and put the upper model to the aticulator. And then tighten the bolt (No. J16) with holding ball cover by hand as shown Fig. 12
Do not contact the end of ball holder to the neck of the ball. (Refer to Fig. 13) In this case, refer to making plaster model. (Instruction 1-⑤)

④ Separate the model which is fixed by dental wax and start working.


Product Inquiry

Your Name:
Your E-Mail:
Telephone Number:
Fax Number:
Your Country & Territory:
Address:
Subject:
Product Quantity Looking for:
Your Message:

Note: Please clealry menction the product/product names, Model, Size & other specifications that will help us to reply you as soon as possible.
Additional Details Required:
  • Minimum Order Quantity
  • Payment Terms
  • More Product Details
  • Availability / Cost
  • Shipping Details
  • Certificates
  • Expected Delivery Lead Time
Confirm Text:    captcha
 

Purchase Product Catalog

Payment & Shipping Conditions:
  • Payment: We accept payment through Paypal Only.
  • Shipping: We will ship the catalog once the payment is received. And you will be receiving the catalog with in 10 -14 busines days. Shipping might be delayed in due to international shipping conditions which is depends on the countries receiveing. In case hard copy of catalog is not available then we will ship the soft copy.
  • Refund: We can refund the order before shipping process was initiated. Incase Catalog not available, we will make sure to refund the order.
  • Note: This is a Catalog Produt.

Products Categories

Products Keywords

Share Gypsum Free Articulator joy Art-1,2/Arti-SB in Social Media