Bunched Cable Vertical Flame Spread Tester, VFT-716, IEC 60332-3, KS C IEC 60332-3-10, 21~25
Introduction
FESTEC's Bunched Cable Vertical Flame Spread Tester is a series conforming to IEC 60332-3-10, KS C IEC 60332-3-21~25 (Category A~D) standards. The test measures the expansion of vertical flame to the electronically or optically vertical cable or wire using the standard ignition source while supplying a certain amount of air to a chamber of a defined volume.Additionally, if bunched cable vertical flame spread tester's burner is adjusted by 20 degrees angle, it can be measure under IEEE 383(IEEE 1202) standard. Also, if Heat Release Facility is attached, it can measure fire dynamics value as H.R.R (Heat Release Rate), S.P.R (Smoke Production Rate) and so on.
Standard
IEC 60332-3-10 : Test on Electric cables under fire conditions part 3 : Test on bunched wires or cables
EN 50399 : common test methods for cables under fire conditions
KS C IEC 60332-3-21 : Category A F/R
KS C IEC 60332-3-22 : Category A
KS C IEC 60332-3-23 : Category B
KS C IEC 60332-3-24 : Category C
KS C IEC 60332-3-25 : Category D
Features
Test chamber has the dimension of 1,000±100(W) x 2,000±100(D) x 4,000±100(H)mm. The bottom surface of the test chamber is higher than the ground while the rear side is supplemented with insulated material to insulate it from heat.
At the lower section of the test chamber, there is a 800±20(W) x 400±10(D) sized hole at the 150±10mm position from the front side of the chamber to supply the air.
There is a 300±30(W) x 1,000±100(D) sized exhaust hole at the rear corner of the top section of the test chamber to allow emission of the smoke during the test.
A flame trap is installed at the front side of the burner of the vertical flame spread tester to prevent backfire by propane to ensure the utmost safety.
Unlike the conventional IEC60332-3 equipment, the vertical flame spread tester records all control and test conditions with the computer to add user friendliness.
The air and gas flow rate to the burner must be compensated for the temperature and pressure. While many conventional systems ignore such compensation, the equipment from FESTEC International automatically compensates it by the computer program.
If stop the excessive combustion test due to Water Spray device installed for extinguish.
The program on the requirement on standard and 70,000Btu/h can be program.
Follow the standard category can program for select a test.
Specification
Model
FT-VFT-716
Size
1,165(W) x 2,165(D) x 4,350(H)mm
Size(Control)
600(W) x 750(D) x 1600(H)mm
Power
AC 220V, 50/60Hz, 15A
Weight
1500kg
Manual
Supply
Exhaust
5,000L/min(inlet), 25m3/min(extraction)
Utilities
Propane Gas, Compressed Air, Water(option), Dust Collector
Test Result
Flameout Time
Chamber Average Temperature
Max. Chamber Temperature
Min. Chamber Temperature
Burner Average Temperature
Max. Burner Temperature
Min. Burner Temperature
Average Inlet Flow(L/Min)
Average Outlet Flow(m/sec)
Average Heat Energy
Total Gas Flow rate
Add photo feature of carbonization area(length)
Bunched Cable Vertical Flame Spread Tester
Description
Product Inquiry
Purchase Product Catalog
Payment & Shipping Conditions:
- Payment: We accept payment through Paypal Only.
- Shipping: We will ship the catalog once the payment is received. And you will be receiving the catalog with in 10 -14 busines days. Shipping might be delayed in due to international shipping conditions which is depends on the countries receiveing. In case hard copy of catalog is not available then we will ship the soft copy.
- Refund: We can refund the order before shipping process was initiated. Incase Catalog not available, we will make sure to refund the order.
- Note: This is a Catalog Produt.
Share Bunched Cable Vertical Flame Spread Tester in Social Media