UL-94 AVH Chamber, UL-511, UL-P11, ASTM D 5048, ASTM D 3801, ASTM D 4804, ASTM D 4986, ISO 10351,ISO 1210, ISO 9772,3, IEC 707
Introduction
UL 94 measures the combustion properties (after flame, after glow) by burner (H-5025 UL tirrill burner) when test sample combusts in chamber's internal volume of 0.864m3 and is installed internal light to observe the specimen's properties and has ventilating opening with emission fan to remove the combustion gas.FESTEC's UL 94-AVH has auto specimen moving system for protecting user from hazardous gas and auto burner moving system for meeting the whole test standards. This auto burner moving system has a goniometer, so it can change the angle of flame to the specimen (0°, 20°, 30°, 45°, 90°).Control box and remote controller help user to handle this equipment or check after flame time and after glow time during testing and are able to adjust the angle.
Standard
Horizontal Burning Test : UL 94HB (ASTM D 5048 or ISO 10351).
Vertical Burning Test : UL 94 V-0, V-1, or V-2 (ASTM D 3801, IEC 707, or ISO 1210).
500w (125mm) Vertical Burning Test : 5VA or 5VB (ASTM D 4804 or ISO 9773).
Thin Material Vertical Burning Test : VTM-0, VTM-1, or VTM-2 (ASTM D 4804 or ISO 9773)
Horizontal Burning Foamed Material Test : HBF, HF-1, or HF-2 (ASTM D 4986 or ISO/ DIS 9772.3)
KS M 3015 : Testing method for thermosetting plastics
KS M 3305 : Liquid unsaturated polyester resins for fiber reinforced plastics
KS M 3809 : Thermal insulation material made of rigid urethane foam
KS M ISO 9772 : Cellular plastics-Determination of horizontal burning characteristics of small specimens subjected to a small flame
Features
Auto specimen moving system (The Switch 'MOVE 1' in the control box enables random control and operation by user) facilitating automatic movement and removal of sample to the ignition source
Auto Burner Moving System (The Switch and Remote Controller switch 'MOVE 2 & 3' in the control box enables random control and operation by user) enabling adjustment of different ignition time and burner angles by each standards
Cable Handy Remote Controller facilitating operation of Timer 1, 2 and 3 in the UL 94-AVH Control Box and Auto Burner Moving System
Double-coated chamber equipped with exhaust fan to readily discharge combustion gas and internal lighting, whose internal volume is 0.864m3
Burner Calibration Kit to measure 20mm of flame and 125mm of flame under ASTM D 5207 (Copper slug thermocouple and digital thermal indicator for 20mm of flame and 125mm of flame)
Thermal Indicator and Thermocouple Connector in the control box facilitating calibration of flame calories by the Copper Slug(ASTM D 5207)
Burner complying with ASTM D 5025 equipped with the precision control system including goniometer facilitating adjustment of burner angles (0°, 20°, 30°, 45°, 90°) frame and gas flow meter in addition to manometer
Control Box adjustable at intervals of 30 degrees facilitating time adjustment and operation of the timer by user' slocation
Sliding Door made of reinforced glass to observe sample and prevent user from inhaling noxious gases during test
2 access ports on the front of the chamber to protect user from inhaling noxious gases, adjust the burner and devices in the chamber and move and fix samples
Clamp facilitating separation and attachment(easy to removable) of test sample
Units and accessories to change flame shape and burner angle in diverse test methods by standards (For example, accessories capable of HBF, HF and ISO 9772 tests)
3 digital timers to measure simultaneously the time of after flame, after glow and after light the touch screen panel PC
Window 2 Step Locking System easy to handle the specimen
Three select options : Manual, Semi-Auto, Full Auto Type
Specification
Model
FT-UL-511, FT-UL-P11
Size
1,600(W) x 650(D) x 1,620(H)mm
Size(Table)
2,500(W) x 800(D) x 600(H)mm
Power
AC 220V, 50/60Hz, 10A
Weight
100kg
Manual
Supply
Exhaust
50L/s
Utilities
Compressed Air, Methane, , Dust Collector
Test Result
After flame : Flame continued even after a firing source disappears
After flame Time : Time taken for after flame continued under specified conditions (unit: second)
After glow : Glowing combustion continued even after an ignition source and flame disappear
After glow Time : Time taken for after glow continued under specified conditions (unit: second)
Damaged length (Damaged length of test sample, unit: mm)
Ignited the cotton indicator by drip flaming(Ignition of cotton by a dropped flame piece) After glow
UL 94 - AVH Chamber
Description
Product Inquiry
Purchase Product Catalog
Payment & Shipping Conditions:
- Payment: We accept payment through Paypal Only.
- Shipping: We will ship the catalog once the payment is received. And you will be receiving the catalog with in 10 -14 busines days. Shipping might be delayed in due to international shipping conditions which is depends on the countries receiveing. In case hard copy of catalog is not available then we will ship the soft copy.
- Refund: We can refund the order before shipping process was initiated. Incase Catalog not available, we will make sure to refund the order.
- Note: This is a Catalog Produt.
Share UL 94 - AVH Chamber in Social Media