Description

Test on Gas Evolved during combustion of electric cables tester, Cable Halogen, PH & ConductivityTester, HCT-717, IEC 60754-1, IEC 60754-2, KS C IEC 60754-1, KS C IEC 60754-2, KWS 409 (5.12) Introduction FESTEC's IEC 60754-1&2 Tester measures gas volume of Halogen Acid (IEC 60754-1), pH concentration(PH Meter, Hydrogen ions, IEC 60754-2), Conductivity(IEC 60754-2) and etc. from a wire (cable) by radiant heat in the Tube Furnace (IEC 60754-1: 800°c, IEC 60754-2: 950°c) Especially, FESTEC's IEC 60754-1&2 is enable to test both IEC 60754-1 and IEC 60754-2 standards by one equipment and mode select function.IEC 60754-1 is halogen-free cable came from and including the polymer to halogenated compounds on the basis of the additive compounds emitted during combustion, except the fluoridation hydracids, it is measure for gas of halogen volume, IEC 60754-2 for electrical or optical cable from compounds emitted during the combustion of measure the gas of oxidation limit. These FESTEC's IEC 60754-1&2 Tester is required by IEC standard. About reproducibility of the test, reliability and convenience of the user to insert the automatic feed devices for combustion boat, turning-rail for easy to put the specimen, the setting of automatic timer, air filtering and etc. this is all feature of FESTEC'S IEC 60754-1&2. Standard IEC 60754-1 Ed. 2.0 b:1994 Test on gases evolved during combustion of materials from cables - Part 1: Determination of the amount of halogen acid gas IEC 60754-2 Ed. 1.0 b:1991 Test on gases evolved during combustion of electric cables - Part 2: Determination of degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring pH and conductivity KS C IEC 60754-1 Tests on gases evolved during combustion of electric cables - Part 1: Measurement of the amount of halogen acid gas KS C IEC 60754-2 Tests on gases evolved during combustion of electric cables - Part 2: Corrosiveness test by generating combustion gases KWS 409 : Wire of Fire Resistance (Fire-Resistence) - 5.12 Causticity for Combustion gas Features Activated Charcoal (air filtering): Filter for filtering the supplied air (activated charcoal) Silica Gel (air drying): Device for drying the supplied air Pyrex tube rail: Easy to insert specimen to prex furnace tube and prevent broken this tube Combustion Boat Moving System: Device for moving combustion boat automatically Mode S/W: Mode conversion switch (Test method of IEC 60754-1&2 could be selected.) Alarm Temperature Controller: Temp controller to protect overheating of furnace Timer: Device for measuring time in experiment per IEC 60754-1 or IEC 60754-2 Drawer: Device for storing test instruments (Example : Conductivity Meter & PH Meter, etc.) Tube is using fire resistance tube made for resist silicon dioxide for protect form the corrosion gas Inside the Furnace of measuring central-temperature Thermocouple for plating by platinum Put specimen easily, and protect for frequent brokenness, it installed for rail During test, made by combustion boat can move to automatically, end of test combustion boat move to outside Furnace automatically Avoid overheating of Furnace for it instill the Alarm Temperature Controller Magnet Stirrer: Stirrer for mixing combustion gas in distilled water PH(Potential of Hydrogen) : Measuring for Oxygen, it supply for PH Meter Conductivity meter: Device for measuring conductivity of combustion gas Specification Model FT-HCT-717 Size 1,500(W) x 500(D) x 600(H)mm Size(Control) 2,300(W) x 500(D) x 800(H)mm Power AC 220V, 50/60Hz, 15A Weight 60kg Manual Supply Exhaust Minimum 50L/s Utilities Compressed Air, PH Meter, Conductivity Meter, Magnetic Stirrer, Dust Collector Test Result Measurement of the amount of halogen Acid gas [It is displayed in milligram of HCl per gram of the measured sample.] (The amount of Halogen Acid) Corrosiveness test by generating combustion gases Average value: Users have to test 3 test times and get values shall be measured and mean value, standard deviation, coefficient of variation shall be calculated.(Calculate the average value, standard deviation and coefficient of Variation.) pH Concentration of weight Conductivity of weight

Product Inquiry

Your Name:
Your E-Mail:
Telephone Number:
Fax Number:
Your Country & Territory:
Address:
Subject:
Product Quantity Looking for:
Your Message:

Note: Please clealry menction the product/product names, Model, Size & other specifications that will help us to reply you as soon as possible.
Additional Details Required:
  • Minimum Order Quantity
  • Payment Terms
  • More Product Details
  • Availability / Cost
  • Shipping Details
  • Certificates
  • Expected Delivery Lead Time
Confirm Text:    captcha
 

Purchase Product Catalog

Payment & Shipping Conditions:
  • Payment: We accept payment through Paypal Only.
  • Shipping: We will ship the catalog once the payment is received. And you will be receiving the catalog with in 10 -14 busines days. Shipping might be delayed in due to international shipping conditions which is depends on the countries receiveing. In case hard copy of catalog is not available then we will ship the soft copy.
  • Refund: We can refund the order before shipping process was initiated. Incase Catalog not available, we will make sure to refund the order.
  • Note: This is a Catalog Produt.

Products Categories

Products Keywords

Share IEC 60754-1&2 (Halogen, PH & Conductivity ... in Social Media