Test on Gas Evolved during combustion of electric cables tester, Cable Halogen, PH & ConductivityTester, HCT-717, IEC 60754-1, IEC 60754-2, KS C IEC 60754-1, KS C IEC 60754-2, KWS 409 (5.12)
Introduction
FESTEC's IEC 60754-1&2 Tester measures gas volume of Halogen Acid (IEC 60754-1), pH concentration(PH Meter, Hydrogen ions, IEC 60754-2), Conductivity(IEC 60754-2) and etc. from a wire (cable) by radiant heat in the Tube Furnace (IEC 60754-1: 800°c, IEC 60754-2: 950°c) Especially, FESTEC's IEC 60754-1&2 is enable to test both IEC 60754-1 and IEC 60754-2 standards by one equipment and mode select function.IEC 60754-1 is halogen-free cable came from and including the polymer to halogenated compounds on the basis of the additive compounds emitted during combustion, except the fluoridation hydracids, it is measure for gas of halogen volume, IEC 60754-2 for electrical or optical cable from compounds emitted during the combustion of measure the gas of oxidation limit. These FESTEC's IEC 60754-1&2 Tester is required by IEC standard. About reproducibility of the test, reliability and convenience of the user to insert the automatic feed devices for combustion boat, turning-rail for easy to put the specimen, the setting of automatic timer, air filtering and etc. this is all feature of FESTEC'S IEC 60754-1&2.
Standard
IEC 60754-1 Ed. 2.0 b:1994 Test on gases evolved during combustion of materials from cables - Part 1: Determination of the amount of halogen acid gas
IEC 60754-2 Ed. 1.0 b:1991 Test on gases evolved during combustion of electric cables - Part 2: Determination of degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring pH and conductivity
KS C IEC 60754-1 Tests on gases evolved during combustion of electric cables - Part 1: Measurement of the amount of halogen acid gas
KS C IEC 60754-2 Tests on gases evolved during combustion of electric cables - Part 2: Corrosiveness test by generating combustion gases
KWS 409 : Wire of Fire Resistance (Fire-Resistence) - 5.12 Causticity for Combustion gas
Features
Activated Charcoal (air filtering): Filter for filtering the supplied air (activated charcoal)
Silica Gel (air drying): Device for drying the supplied air
Pyrex tube rail: Easy to insert specimen to prex furnace tube and prevent broken this tube
Combustion Boat Moving System: Device for moving combustion boat automatically
Mode S/W: Mode conversion switch (Test method of IEC 60754-1&2 could be selected.)
Alarm Temperature Controller: Temp controller to protect overheating of furnace
Timer: Device for measuring time in experiment per IEC 60754-1 or IEC 60754-2
Drawer: Device for storing test instruments (Example : Conductivity Meter & PH Meter, etc.)
Tube is using fire resistance tube made for resist silicon dioxide for protect form the corrosion gas
Inside the Furnace of measuring central-temperature Thermocouple for plating by platinum
Put specimen easily, and protect for frequent brokenness, it installed for rail
During test, made by combustion boat can move to automatically, end of test combustion boat move to outside Furnace automatically
Avoid overheating of Furnace for it instill the Alarm Temperature Controller
Magnet Stirrer: Stirrer for mixing combustion gas in distilled water
PH(Potential of Hydrogen) : Measuring for Oxygen, it supply for PH Meter
Conductivity meter: Device for measuring conductivity of combustion gas
Specification
Model
FT-HCT-717
Size
1,500(W) x 500(D) x 600(H)mm
Size(Control)
2,300(W) x 500(D) x 800(H)mm
Power
AC 220V, 50/60Hz, 15A
Weight
60kg
Manual
Supply
Exhaust
Minimum 50L/s
Utilities
Compressed Air, PH Meter, Conductivity Meter, Magnetic Stirrer, Dust Collector
Test Result
Measurement of the amount of halogen Acid gas [It is displayed in milligram of HCl per gram of the measured sample.] (The amount of Halogen Acid)
Corrosiveness test by generating combustion gases
Average value: Users have to test 3 test times and get values shall be measured and mean value, standard deviation, coefficient of variation shall be calculated.(Calculate the average value, standard deviation and coefficient of Variation.)
pH Concentration of weight
Conductivity of weight
IEC 60754-1&2 (Halogen, PH & Conductivity ...
Description
Product Inquiry
Purchase Product Catalog
Payment & Shipping Conditions:
- Payment: We accept payment through Paypal Only.
- Shipping: We will ship the catalog once the payment is received. And you will be receiving the catalog with in 10 -14 busines days. Shipping might be delayed in due to international shipping conditions which is depends on the countries receiveing. In case hard copy of catalog is not available then we will ship the soft copy.
- Refund: We can refund the order before shipping process was initiated. Incase Catalog not available, we will make sure to refund the order.
- Note: This is a Catalog Produt.
Share IEC 60754-1&2 (Halogen, PH & Conductivity ... in Social Media