Introduction
Max. Cutting Capacity 32mm Bending Angle 45-180 Working speed 6sec/180degree Power 220V 50/60Hz Size (mm) 480x465x470 Weight (kg) 105
Feature
The potable rebar bender is suitable for use on the construction site.
Fast and easy change of angles with two control levers attached to present the bending angles. (Available angle :
-
FESTEC’s Building Construction Fire Resistance Tester measures the performance of construction material against standard fire conditions, and satisfies the general requirements, vertical history section material, vertical non-history section material and the fire-proof door’s fire proof testing.@ This equipment tests about the walls, doors,
-
FESTEC’s IEC 60331-11 tester is used in test conditions where the basic flame temperature is at least 750? and tests the cable exposed to the flame that needs to maintain the circuit
-
Slipring
The brush type slipring is an electrical parts transferring a power and some kinds of signals
without twist of wires between rotor and stator.
As using a precious metal brush,
the brush type slipring solve the problems which are occurring
in carbon type slipring like electrical noise, maintenance, life cycle and so
-
In oxygen treatment patient by a direct suction and at the same time when the patient inhales oxygen, it's device to regulate humidity in the body through atomizing therapy.
PRIMARY SPECIFICATIONS
Model : MM-BJ015A0
Construction
* Flow range : Dual taper 0 ~ 15 LPM
* Increments : 0.5 LPM from 0.25 to 6 LPM
1
-
Thoracic suction unit is a lightweight, compact unit used throughout the hospital for chest and mediastinal drainage.
The unit has a double chamber, which provides an adjustable vacuum of 0 to 25Cm H2O and housed in double polycarbonate bottle.
One chamber is using a water manometer with water level, the other serving as the underwater seal
-
Features
* Type : Movable stand type
* Versatile stand slide bracket for control of height
* Collection unit provide reliable over-flow protection
* Regulated vacuum range : 0 ~ 200mmHg w/full line
* Two line selection control vacuum (Line 1 / Off / Line 2)
* Full / Off / Regulated vacuum - one touch change
* On/Off selector use without
-
With connecting to vacuum outlet, it's device to remove lots of foreign substance from a surgical patient.
It's pressure can be used as regulating properly.
Features
* Type : Movable kick type
* Collection unit provide reliable over-flow
protection
-
It consists of suction regulator and suction container. With connecting to vacuum outlet of hospital and as regulating pressure properly, it's device to remove a foreign substance from patient. Separating suction trap unit has an automatical opened and closed floating valve taking double protection function against a foreign substance. And it
-
With connecting to portable oxygen cylinder, it's device to supply oxygen to patient as regulating artificial oxygen flow.
Features
Single-stage Oxygen pressure regulator with a flowmeter and humidifier. * Inlet Pressure : 150 Kgf/Cm2 (2134 PSIG) * Outlet Pressure : 3.0 Kgf/Cm2 (43 PSIG) * Outlet Flowrate : 0 ~ 15 Liter/Min * Remarks :
-
With connecting to gas outlet, it's device to supply oxygen to patient as regulating artificial oxygen flow. It has a merit not to be broken easily with strong durability and it's smooth surface treatment with polycarbonate glass materials, too.
Features
* Bubble type Humidifier for Oxygen
* Calibrate 3.5 Kg/Cm2 (50PSIG) inlet
-
t's system to supply medical gas and sources of electricity through an external case. First it makes a mold fixed and installed to concrete roof in the ceiling of OR and the mold has been adhered to an external case included devices (receptacle and check valve) to supply medical gas and sources of electricity to anesthetic machine and some
-
It's system that outlets of medical gas have been installed in ceiling of OR, Delivery Room and Premature Room which is hard wards to install outlets in the side wall. This system is for Rim Drum method that in using it, if pull it down and stop it, it stops at that place and after using it, if pull it down again, it stops to comp up over
-
It's system to supply medical gas and sources of electicity through column attached receptacle and check valve and installed and the column moves up and down and fixes to concrete roof in the ceiling of OR.
Type
Vacuum powerd retractable type
None-retractale fixed position type
Construction
* box : Stainless steel 1.2t
-
It's general system installed from one outlet to five outlets at wall side of OR, Treatment Room and general ward through safety device to use each gas smoothly supplied from cental supply system of medical gas. This system have structure that gas flows just to fix adapter in use and gas confirmly closes just to draw out it from outlet. Also
-
This system is for education to nurse which reconstructs console unit installed at the upper wall side of bed to offer an electric power and medical gas for patient treatment. As it's for education to nurse, this system takes the focus on more independent and free movement.
-
It's an intensive care system for a serious care that equips electric power, medical oxygen, medical vacuum, personal reading light, nurse call on one panel to treat efficiently patients. This system fixs and installs on wall side in ICU to nurse and manage patients easily so that also offers more safe and efficient care circumstance to
-
It's an intensive care system for a serious care that equips electric power, medical oxygen, medical vacuum, personal reading light, nurse call on one panel to treat efficiently patients. This system fixs and installs on wall side in ICU to nurse and manage patients easily so that also offers more safe and efficient care circumstance to
-
It's a general ward care system that equips electric power, medical oxygen, medical vacuum, personal reading light, nurse call on one panel to treat efficiently patients. This system fixs and installs on wall side in a general ward to nurse and manage patients easily so that also offers more safe and efficient care circumstance to patients and
-
THE SKIN COOLING SYSTEM FOR LASER TREATM ENTS
ADVANCED SKIN-COOLING SYSTEM
Standby mode - Permits instant user operation
Immediate cooling available for patient treatment
9fan speeds ensure optimum airflow selection
The Cryo Mini cold air system has been created to meet the needs of aesthetic procedures with shorter